Mitsubishi Electronics MDS-D2/DH2 Series Pager User Manual


 
4 - 44
4 Setup
MITSUBISHI CNC
#2238 SV038 FHz1 Notch filter frequency 1
Set the vibration frequency to suppress when machine vibration occurs.
(Normally, do not set 80 or less.)
Set to "0" when not using.
Related parameters: SV033/bit3-1, SV115
---Setting range---
0 to 2250 (Hz)
#2239 SV039 LMCD Lost motion compensation timing
Set this when the timing of lost motion compensation type 2 does not match.
Adjust increments of 10 at a time.
---Setting range---
0 to 2000 (ms)
#2240 SV040 LMCT Lost motion compensation non-sensitive band
Set the non-sensitive band of the lost motion compensation in the feed forward control.
When "0" is set, 2μm is the actual value to be set. Adjust increments of 1μm.
---Setting range---
0 to 255 (μm)
#2241 SV041 LMC2 Lost motion compensation 2
Set this with SV016 (LMC1) only when you wish to vary the lost motion compensation amount
depending on the command directions.
Normally, set to "0".
---Setting range---
-1 to 200 (Stall current %)
Note that when SV082/bit2 is "1", the setting range is between -1 and 20000 (Stall current
0.01%).
#2242 SV042 OVS2 Overshooting compensation 2
Set this with SV031 (OVS1) only when you wish to vary the overshooting compensation amount
depending on the command directions.
Normally, set to "0".
---Setting range---
-1 to 100 (Stall current %)
Note that when SV082/bit2 is "1", the setting range is between -1 and 10000 (Stall current
0.01%).
#2243 SV043 OBS1 Disturbance observer filter frequency
Set the disturbance observer filter band.
Normally, set to "100". Setting values of 49 or less is equal to "0" setting.
To use the disturbance observer, also set SV037 (JL) and SV044 (OBS2).
When disturbance observer related parameters are changed, lost motion compensation needs to be
readjusted.
Set to "0" when not using.
---Setting range---
0 to 1000 (rad/s)