Mitsubishi Electronics MDS-D2/DH2 Series Pager User Manual


 
4 - 144
4 Setup
MITSUBISHI CNC
#13087 SP087 FHz4 Notch filter frequency 4
Set the vibration frequency to suppress when machine vibration occurs.
(Enabled at 50 or more.)
When not using, set to "0".
Related parameters: SP034/bitB-9
---Setting range---
0 to 2250 (Hz)
#13088 SP088 FHz5 Notch filter frequency 5
Set the vibration frequency to suppress when machine vibration occurs.
(Enabled at 50 or more.)
When not using, set to "0".
Related parameters: SP034/bitF-D
---Setting range---
0 to 2250 (Hz)
#13089 SP089 TMKQ Spindle output stabilizing gain Q axis
Set the magnification of the torque current stabilizing gain. (For machine tool builder adjustment)
When set to "0", the torque current stabilization is disabled.
When not using, set to "0".
---Setting range---
0 to 32767
#13090 SP090 TMKD Spindle output stabilizing gain D axis
Set the magnification of the excitation current stabilizing gain. (For machine tool builder adjustment)
When set to "0", the excitation current stabilization is disabled.
When not using, set to "0".
---Setting range---
0 to 32767
#13091 SP091
Not used. Set to "0".
#13092 SP092
Not used. Set to "0".
#13093 SP093
Not used. Set to "0".
#13094 SP094 MPV Magnetic pole error detection speed
In the magnetic pole position detection function, the command motor speed and motor speed during
the position command stop are monitored.
Set the command motor speed level and motor speed level during the position command stop in "r/
min" unit.
When the command motor speed level is set to "0", the magnetic pole position error is detected at
10r/min.
Set to "10" as a standard setting when the magnetic pole position error detection function is enabled.
This detects the magnetic pole position error when the motor speed is "100r/min".
Ten-thousands digit, Thousands digit ------------ Command motor speed level (10r/min)
Hundreds digit, Tens digit, Ones digit ----------- Motor speed level (10r/min)
---Setting range---
0 to 31999