Mitsubishi Electronics MDS-D2/DH2 Series Pager User Manual


 
4 - 93
MDS-D2/DH2 Series Instruction Manual
4.3 Setting the Initial Parameters for the Spindle Drive Unit
SP078 IDA D axis current lead compensation 4096 4096 4096
SP079 IQG Q axis current gain 1024 1024 1024
SP080 IDG D axis current gain 1024 1024 1024
SP081 IQAL Q axis current lead compensation low-speed coil 000
: :::
SP088 FHz5 Notch filter frequency 5 000
SP089 TMKQ Spindle output stabilizing gain Q axis 000
SP090 TMKD Spindle output stabilizing gain D axis 000
: :::
SP112 000
SP113 OPLP Current command value for open loop 000
SP114 MKT Coil changeover gate cutoff timer 150 150 150
SP115 MKT2 Coil changeover current limit timer 250 250 250
SP116 MKIL Coil changeover current limit value 120 120 120
SP117 SETM Excessive speed deviation timer 12 12 12
SP118 MSFT Magnetic pole shift amount 000
SP119 000
: :::
SP128 DA2MPY D/A output ch2 output scale 000
SP129 PM Motor unique constants (H) 222
SP130 JM Motor unique constants (H) 58 80 80
SP131 ATYP Motor unique constants (H) 100 160 160
SP132 000
SP133 NR Motor unique constants (H) 8000 8000 8000
SP134 NB Motor unique constants (H) 1250 1250 1100
SP135 NF Motor unique constants (H) 1250 1250 1100
SP136 KT Motor unique constants (H) 3365 3548 3394
SP137 KF1 Motor unique constants (H) 73 59 68
SP138 KF2 Motor unique constants (H) 2865 2942 2830
SP139 KF3 Motor unique constants (H) 2755 2724 2888
SP140 KF4 Motor unique constants (H) 1919 1917 1899
SP141 KF5 Motor unique constants (H) 191 201 190
SP142 KF6 Motor unique constants (H) 000
SP143 000
SP144 TMIL Motor unique constants (H) 000
SP145 TMBR Motor unique constants (H) 382 350 433
SP146 TMBD Motor unique constants (H) 435 437 436
SP147 KE Motor unique constants (H) 63 61 64
SP148 LA Motor unique constants (H) 2771 2199 1862
SP149 IQSM Motor unique constants (H) 3406 3983 5627
SP150 IDSM Motor unique constants (H) 1367 1755 2091
SP151 R1 Motor unique constants (H) 234 164 141
SP152 TMLR Motor unique constants (H) 90 90 90
SP153 TMLD Motor unique constants (H) 120 120 120
SP154 TMLS Motor unique constants (H) 150 150 150
SP155 KI1 Motor unique constants (H) 1038 1034 1039
SP156 PCNT Motor unique constants (H) 000
SP157 000
SP158 DNB Motor unique constants (H) 750 743 750
SP159 SNB Motor unique constants (H) 750 743 750
SP160 BSD Motor unique constants (H) 000
SP161 000
: :::
SP224 000
SP225 SFNC5 Spindle function 5 0000 0000 0000
SP226 SFNC6 Spindle function 6 0000 0000 0000
SP227 SFNC7 Spindle function 7 0000 0000 0000
: :::
SP232 0000 0000 0000
SP233 IVC Voltage non-sensitive band compensation 000
SP234 000
SP235 R2H Temperature compensation gain 000
SP236 WIH Temperature compensation time constant 000
SP237 TCF Torque command filter 500 500 500
SP238 SSCFEED Safely limited speed 000
SP239 SSCRPM Safely limited motor speed 000
SP240 000
:
SP256
Motor
Parameter
400V Standard motor SJ-4-V Series (Wide range constant output)
SJ-4-V15-20T SJ-4-V18.5-17T SJ-4-V22-16T
No. Abbrev. Details MDS-DH2-SP- 100 160 160