Appendix 2.1 CMV1-xPxxS-xx Plug Connector
(Note) Make sure that the core wire does not come out of the contact.
When soldering, make sure that the solder does not stick to the circumference of the solder cup.
When using a drain wire, attach a heat shrink tube to the drain cable after soldering.
* When making CMV1-xP10S-xx, the cable for No. 10 terminal is 1mm longer than other cables. (To avoid
the core tension when inserting a contact to the housing in a later process.)
* The difference in the total A length of the cables for other than No. 10 terminal must be 1mm or less.
(5) Inserting the contact
Insert the contact into the specified terminal number point in
the housing.
(Insert grounding wire or drain wire into terminal No. 10).
* When the contact catches the housing, you will hear
a snap.
* Pulling the wire for confirming the correct position.
(Note) Before inserting the contact, check that the clamp nut, cable clamp, bushing and back shell is inserted.
Take care not to insert the contact upside down as shown below.
* Insert the contact so that the terminal number face the same
direction.
* Using a pull out tool for pulling up inserted contact.
Tool No.: 357J-53184T
Refer to the instruction manual in case of using pull up tool.
* As Lance falls down easily after pulling up, set up to original
position before re-insert.
C
Detail C
Solder
Contact
Core wire
Cable
Drain wire
Heat shrink tube
Difference in total length: 1 mm or less
(for other than No. 10 terminal)
If a drain wire is soldered
Cable
Housing
Contact
Terminal No.10 only
(Grounding wire or drain wire)
Insert
Terminal number
Lance
Contact
Terminal number
Lance
Contact
CMV1-xP2S-xx
CMV1-xP10S-xx