Mitsubishi Electronics MDS-D2/DH2 Series Pager User Manual


 
7 - 38
7 Troubleshooting
MITSUBISHI CNC
Warning No.
E1
Overload warning
Overload detection level exceeded 80%.
Investigation details Investigation results Remedies SV SP
1 Check if the motor is hot.
Motor is hot. Check the alarm No. "50" items.
Motor is not hot. Check the investigation item No. 2.
2
Check if an error occurs when executing
acceleration/deceleration operation.
Error is not found in operation. Thus,
operation is possible.
Ease the operation patter, if possible. If no
alarm occurs, operation can be continued as
it is.
Error is found in operation.
Check the investigation item 3 or later of
Alarm No. 50.
3 Check the alarm No. "50" items.
◯◯
Warning No.
E4
Set parameter warning
An incorrect parameter was detected among the parameters received from the CNC.
Investigation details Investigation results Remedies SV SP
1 Check the error parameter No.
SV001 to SV256
SP001 to SP256
Set the value within the designated setting
range.
◯◯
2 Check the spindle control input 4/bit 0 to 2.
Selected other than 000, 001, 010 and 100
when the alarm occurred.
Correctly select.
Warning No.
E6
Control axis detachment warning
Control axis detachment was commanded.
Investigation details Investigation results Remedies SV SP
1 The status in which removal of the control axis was commanded from the NC is indicated.
Warning No.
E7
In NC emergency stop state
Emergency stop was input from the CNC.
Investigation details Investigation results Remedies SV SP
1
Check if the emergency stop is applied on the NC
side.
The emergency stop is applied. Check the investigation item No. 2.
◯◯
The emergency stop is cancelled. Check the investigation item No. 3.
2 Cancel the emergency stop.
Normally starts up. Normal.
◯◯
"E7" remains displayed. Check the investigation item No. 3.
3
Check whether an alarm is occurring in another
drive unit.
An alarm is occurring in another drive unit. Reset the alarm in the other drive unit.
◯◯
An alarm is not occurring. Check the investigation item No. 4.
4 Turn the power of NC and 200VAC (400V) ON again
◯◯
Warning No.
E9
Instantaneous power interruption warning
The power was momentarily interrupted.
Investigation details Investigation results Remedies CV
1 Check the alarm No. "71" items.
Warning No.
EA
In external emergency stop state
External emergency stop signal was input.
Investigation details Investigation results Remedies CV
1
Check whether the specifications allow use of the
external emergency stop.
Use is not allowed. Invalidate the external emergency stop.
Use is allowed. Check the investigation item No. 2.
2
Measure the input voltage of the CN23 connector.
(While emergency stop is cancelled.)
24V is input. Replace the power supply unit.
24V is not input.
Check whether the external emergency stop
cable is broken, or check the external contact
operation.
Warning No.
EB
Power supply: Over regeneration warning
Over-regeneration detection level exceeded 80%.
Investigation details Investigation results Remedies CV
1 Check the alarm No. "73" items.