Patton electronic SmartNode 4110 Series IP Phone User Manual


 
Basic system management configuration task list 96
SmartWare Software Configuration Guide 7 • Basic system management
Display time since last restart
This procedure describes how to display the time since last restart
Mode: Operator execution
Example:
The following example shows how to display the uptime of your device, if you start from the configuration mode.
node>show uptime
The system is up for 54 days, 23 hours, 44 minutes, 18 seconds
Configuring the Web server
The embedded web server has two parameters that are configurable.
Note Changing the language parameter does not affect the language of the web
configuration pages.
Mode: Configure
Example: Configuring and starting the Web server
The following example shows how to set the web server language and the listening port of your device, if you
start from the configuration mode.
node(cfg)#webserver language en
node(cfg)#webserver port 80
Determining and defining the active CLI version
SmartWare allows having a number of CLI version installed together, whereas only one CLI version is acti-
vated. There are commands available to determine the currently running CLI version and if necessary switch to
another CLI version. The idea of having several CLI version available on a system is mostly to offer reduced or
enhanced command sets to users.
Mode: Configure
Step Command Purpose
1 node>show uptime Display the time since last restart.
Step Command Purpose
1 node(cfg)#webserver language
{de | en}
Sets the language to either German (de) or English (en).
2 node(cfg)#webserver port port-
number
Sets the listening port number in the 1 to 65535, default
port number for the web server is 80.
Step Command Purpose
1 node(cfg)#show version cli Displays the currently running CLI version
2 node(cfg)#cli version version.revision Selects the active CLI version in the form version.revi-
sion