H.323 interface configuration task list 439
SmartWare Software Configuration Guide 38 • H.323 interface configuration
node(cfg)#context cs
node(ctx-cs)[switch]#interface h323 MyH323If
node(if-h323)[MyH323If]#no status-inquiry
Procedure: To change the default status inquiry interval
Mode: Interface H.323
Example: Disable status inquiries
The following example
the status inquiry interval for the H.323 interface MyH323If to 120 seconds.
node>enable
node#configure
node(cfg)#context cs
node(ctx-cs)[switch]#interface h323 MyH323If
node(if-h323)[MyH323If]#status-inquiry timeout 120
AOC-D Support for H.323
The H.323 gateway is able to accept and send Advice of Charge during the call (AOC-D) messages according
to the ITU-T standard Q.956. Facility Information Elements (IEs) in the Q.931 portion of the protocol are
used to transport AOC-D PDUs. (Refer to “Chapter 28: ISDN interface configuration”, section “ISDN
Advice of Charge support.”)
You can enable/disable reception and transmission of AOC-D messages separately on each H.323 interface.
When reception is enabled, AOC-D messages received in incoming H.323 FACILITY messages are forwarded
to the ISDN side of the call. In addition to the H.323 interface, AOC support must also be enabled on the
ISDN interface (see ISDN Advice Of Charge support section of Chapter 28 ISDN interface configuration of
the Software Configuration Guide).
When transmission is enabled, AOC-D messages received from the ISDN side of the call are sent as H.323
FACILITY to the remote terminal or gatekeeper.
The following commands can be used to change the AOC-D over H.323 tunneling behavior on an H.323
interface:
Step Command Purpose
1
node(if-h323)[if-name]#status-inquiry
timeout seconds
Changes the status inquiry interval on the
interface to the specified number of seconds