Patton electronic SmartNode 4110 Series IP Phone User Manual


 
Serial port configuration task list 173
SmartWare Software Configuration Guide 14 • Serial port configuration
Hardware Port : V.35
Transmit Edge : normal
Port Type : DTE
CRC Type : CRC-16
Max Frame Length: 2048
Recv Threshold : 1
Encapsulation :
Configuring the serial encapsulation type
The synchronous serial interface supports the Frame Relay and PPP serial encapsulation method. For more
information how to configure Frame Relay and PPP, please see Chapter15, “Frame Relay configuration” on
page 177 and Chapter 30, “PPP configuration” on page 313.
To set the encapsulation method used by a serial interface, use the
encapsulation interface
configuration command.
This procedure describes how to set the encapsulation type of the serial interface.
Mode: Administrator execution
Example: Configuring the serial encapsulation type
The following example enables Frame Relay encapsulation for the serial interface on slot 0 and port 0. Check
that in the command output of
show port serial Encapsulation is set to framerelay.
node(cfg)#port serial 0 0
node(prt-ser)[0/0]#encapsulation framerelay
node(prt-ser)[0/0]#show port serial
Serial Interface Configuration
------------------------------
Port : serial 0 0 0
State : CLOSED
Hardware Port : V.35
Transmit Edge : normal
Port Type : DTE
CRC Type : CRC-16
Max Frame Length: 2048
Recv Threshold : 1
Encapsulation : framerelay
Configuring the hardware port protocol
Note Only available on certain devices.
Step Command Purpose
1 node(cfg)#port serial slot port Selects the serial interface on slot and
port.
2 node(prt-ser)[slot/port]#[no] encapsulation
{framerelay | ppp}
Sets the encapsulation type for the
selected interface.
3 node(prt-ser)[slot/port]#show port serial Displays the serial interface configuration.