Lucent Technologies 6.0 Telephone User Manual


  Open as PDF
of 1114
 
MERLIN LEGEND Communications System Release 6.0
System Programming
555-660-111
Issue 1
February 1998
Common Administrative Procedures
Page 4-390Automatic Route Selection
4
N11 Special Numbers Tables 4
Use this procedure to specify Facility Restriction Level (FRL) and/or digits that
must be added when emergency numbers in the N11 Special Numbers table are
dialed (for example, 411, 811, or 911).
Subpattern B, absorb, and pool routing cannot be programmed for the N11
Special Numbers tables.
NOTE:NOTE:NOTE:
In Release 6.0 and later systems, when routing for ARS Special Numbers
N11 calls from a networked switch that is not connected to the public
switched network, the private trunks must be assigned to a pool. The local
system must prepend the ARS access code of the connected switch from
which the calls will be directed to the public switched network.
Summary: N11 Special Numbers Tables 4
Programmable by System Manager
Mode Hybrid/PBX
Idle Condition Not required
Planning Form Form 3g, Automatic Route Selection Default and
Special Numbers Tables
Factory Setting Not applicable
Valid Entries Not applicable
Inspect No
Copy Option No
Console Procedure To change Facility Restriction Level:
More Drop
Dial FRL value
To program other digits:
More
DropDial digits
PC Procedure To change Facility Restriction Level:
+
Type FRL value
To program other digits:
+
Type digits