Page 4-10Basic System Operating Conditions
4
Automatic Maintenance Busy 4
Automatic Maintenance Busy allows the system to take a malfunctioning trunk out
of service for outgoing calls (incoming calls are never blocked). This prevents
faulty outside facilities from causing disruptions in outgoing calling patterns.
For optimal performance, enable Automatic Maintenance Busy for Hybrid/PBX
systems with pooled trunks.
NOTE:NOTE:NOTE:
No more than half of the trunks in a trunk pool are allowed to be placed in
the maintenance busy state at one time unless the central office has failed
to disconnect a trunk (which prevents anyone from using that trunk) or an
entire trunk module is manually taken out of use (a maintenance-busy state
deliberately caused by the user).
Summary: Automatic Maintenance Busy 4
Programmable by System Manager
Mode All
Idle Condition Not required
Planning Form Form 1, System Planning
Factory Setting Disabled
Valid Entries Enabled, Disabled
Inspect No
Copy Option No
Console Procedure To disable Automatic Maintenance Busy:
To enable Automatic Maintenance Busy excluding
tie trunks:
To enable/disable with tie trunks:
or
PC Procedure To disable Automatic Maintenance Busy:
To enable Automatic Maintenance Busy excluding tie trunks:
To enable/disable with tie trunks:
or