MERLIN LEGEND Communications System Release 6.0
System Programming
555-660-111
Issue 1
February 1998
Programming Procedures
Page 4-20System Renumbering
4
Single Renumbering 4
Use this procedure to assign a specified extension number to a telephone,
accessory, line, pool (Hybrid/PBX only), calling group, paging group, or Listed
Directory Number. Single renumbering is also used for Remote Access, Park, Idle
Line Access (Key and Behind Switch only), and Automatic Route Selection
(Hybrid/PBX only).
See “Single Renumbering” on page 3–14
for detailed information.
!
CAUTION:
!
CAUTION:
Select on the console or on the PC after renumbering extensions.
If you press Home, extensions may remain in the forced idle condition
(indicated when the LED next to each DSS button is on). To restore
extensions to their normal operating state, restart the system.
When required, this procedure should be performed immediately following the
selection of a system numbering plan.
Summary: Single Renumbering 4
Programmable by System Manager
Mode All
Idle Condition System idle
Planning Form Form 2a, System Numbering: Extension Jacks
Form 2b, System Numbering: Digital Adjuncts
Form 2d, System Numbering: Special Renumbers
Factory Setting Not applicable
Valid Entries Old and new extension numbers
Inspect Yes
Copy Option No
Console Procedure
Select itemDial old ext. no.
Dial new ext. no.
PC Procedure Select itemType old ext. no.
Type new ext. no.