Lucent Technologies 6.0 Telephone User Manual


  Open as PDF
of 1114
 
MERLIN LEGEND Communications System Release 6.0
System Programming
555-660-111
Issue 1
February 1998
Programming Basics
Page 1-55Product Enhancements
1
Installation and Hardware 1
Installation and hardware enhancements include the following:
The control unit covers for the MERLIN LEGEND Communications System
are the same easy-to-use covers as those for the MERLIN II
Communications System.
A new 012 (tip/ring) module [apparatus code 517G13 (28) or higher letter]
contains a built-in ring generator. The maximum ring equivalency number
(REN) supported is 2.2, and the module will ring four ports at one time.
Bridging of single-line telephones is not supported because of poor
transmission quality.
A new 008 OPT module (labeled “with RING GEN.”) contains a built-in ring
generator. It rings four ports at a time.
Ferrite cores for the power supply modules are shipped from the factory to
comply with FCC Part 15 requirements.
3129-WTWA (touch tone outdoor telephone equipped with cast aluminum
housing and armored handset cord with bell ringers)
3129-WRWA (rotary dial outdoor telephone equipped with cast aluminum
housing and armored handset cord with bell ringers)
3129-WAWA (auto dial outdoor telephone equipped with cast aluminum
housing and armored handset cord with bell ringers)
3129-WNWA (nondial, automatic ringing on dedicated circuit outdoor
telephone equipped with cast aluminum housing and armored handset
cord with bell ringers)
Equipment and Operations 1
Equipment and operations enhancements include the following:
A new release (Version 2.16) of the System Programming and
Maintenance (SPM) software to support international use.
Support of PRI connection to DEFINITY
Communications Systems
MLX-10DP telephone, identical to an MLX-10D, except that it provides a
jack for access to the PassageWay Solution and PassageWay Direct
Connection Solution application.