MERLIN LEGEND Communications System Release 6.0
System Programming
555-660-111
Issue 1
February 1998
Programming Procedures
Page 4-13Basic System Operating Conditions
4
Summary: Set System Date 4
Programmable by. System Manager
Mode All
Idle Condition Not required
Planning Form Form 1, System Planning
Factory Setting 01-01-00
Valid Entries Month: 01 to 12
Day: 01 to 31
Year: 00 to 99
Inspect No
Copy Option No
Console Procedure
DropDial current date
PC Procedure
+
Type current date
Set System Time 4
The System Time feature allows you to set the time that appears on MLX display
telephones and on SMDR reports. See “Set System Time” on page 3–9
for
detailed information.
NOTE:NOTE:NOTE:
In Release 6.0 and later systems, where a MERLIN LEGEND
Communications System switch is networked in a private network with one
or more other MERLIN LEGEND Communications System switches or with
one or more DEFINITY Communications Systems, SMDR reports may
report outgoing calls using more than one call record (for example, for
tandem calls), depending upon how SMDR is programmed and how calls
are routed. If SMDR is reporting outgoing calls and users are employing
private network lines to make these calls, ensure that the system date and
time are set accurately on each system that carries these calls. As you
examine call reports, you may need to be aware of time zone differences
among networked system locations.