RL78/G1A
CHAPTER 30 ELECTRICAL SPECIFICATIONS (G: INDUSTRIAL APPLICATIONS T
A
=
40 to +105
°
C)
R01UH0305EJ0200 Rev.2.00 947
Jul 04, 2013
(4) When reference voltage (+) = AVDD (ADREFP1 = 0, ADREFP0 = 0), reference voltage () = AVSS (ADREFM = 0),
target for conversion: ANI16 to ANI30, interanal reference voltage, temperature sensor output voltage
(T
A = 40 to +105°C, 2.4 V EVDD0 VDD0 3.6 V, 2.4 V AVDD VDD 3.6 V, VSS = EVSS0 = 0 V, AVSS = 0 V,
Reference voltage (+) = AVDD, Reference voltage () = AVSS = 0 V)
Parameter Symbol Conditions MIN. TYP. MAX. Unit
Resolution RES 2.4 V AVDD 3.6 V 8 12 bit
Overall error
Note 1
AINL 12-bit resolution 2.4 V AVDD 3.6 V ±8.5 LSB
Conversion time tCONV
ADTYP = 0,
12-bit resolution
2.4 V AV
DD 3.6 V 4.125
μ
s
Zero-scale error
Note 1
EZS 12-bit resolution 2.4 V AVDD 3.6 V ±8.0 LSB
Full-scale error
Note 1
EFS 12-bit resolution 2.4 V AVDD 3.6 V ±8.0 LSB
Integral linearity error
Note 1
ILE 12-bit resolution 2.4 V AVDD 3.6 V ±3.5 LSB
Differential linearity error
Note 1
DLE 12-bit resolution 2.4 V AVDD 3.6 V ±2.5 LSB
0
AV
DD and
EV
DD0
V
Interanal reference voltage
(2.4 V V
DD 3.6 V, HS (high-speed main) mode)
V
BGR
Note 2
V
Analog input voltage VAIN
Temperature sensor output voltage
(2.4 V V
DD 3.6 V, HS (high-speed main) mode)
V
TMPS25
Note 2
V
Notes 1. Excludes quantization error (±1/2 LSB).
2. See 30.6.2 Temperature sensor, internal reference voltage output characteristics.
<R>