Renesas rl78 Answering Machine User Manual


  Open as PDF
of 1004
 
RL78/G1A CHAPTER 12 SERIAL ARRAY UNIT
R01UH0305EJ0200 Rev.2.00 403
Jul 04, 2013
12.1.3 Simplified I
2
C (IIC00, IIC01, IIC10, IIC11, IIC20, IIC21)
This is a clocked communication function to communicate with two or more devices by using two lines: serial clock
(SCL) and serial data (SDA). This simplified I
2
C is designed for single communication with a device such as EEPROM,
flash memory, or A/D converter, and therefore, it functions only as a master.
Make sure by using software, as well as operating the control registers, that the AC specifications of the start and stop
conditions are observed.
For details about the settings, see 12.8 Operation of Simplified I
2
C (IIC00, IIC01, IIC10, IIC11, IIC20, IIC21)
[Data transmission/reception]
Master transmission, master reception (only master function with a single master)
ACK output function
Note
and ACK detection function
Data length of 8 bits (When an address is transmitted, the address is specified by the higher 7 bits, and the least
significant bit is used for R/W control.)
Manual generation of start condition and stop condition
[Interrupt function]
Transfer end interrupt
[Error detection flag]
ACK error, or overrun error
* [Functions not supported by simplified I
2
C]
Slave transmission, slave reception
Arbitration loss detection function
Wait detection functions
Note When receiving the last data, ACK will not be output if 0 is written to the SOEmn bit (serial output enable register
m (SOEm)) and serial communication data output is stopped. See the processing flow in 12.8.3 (2) for details.
Remarks 1. To use an I
2
C bus of full function, see CHAPTER 13 SERIAL INTERFACE IICA.