RL78/G1A CHAPTER 29 ELECTRICAL SPECIFICATIONS (T
A = 40 to +85°C)
R01UH0305EJ0200 Rev.2.00 861
Jul 04, 2013
(TA = 40 to +85°C, 1.6 V EVDD0 VDD 3.6 V, VSS = EVSS0 = 0 V) (2/3)
Parameter Symbol Conditions MIN. TYP. MAX. Unit
fIH = 32 MHz
Note 4
VDD = 3.0 V 0.54 1.63 mA
fIH = 24 MHz
Note 4
VDD = 3.0 V 0.44 1.28 mA
HS (high-speed
main) mode
Note 7
f
IH = 16 MHz
Note 4
VDD = 3.0 V 0.40 1.00 mA
VDD = 3.0 V 270 530
LS (low-speed
main) mode
Note 7
f
IH = 8 MHz
Note 4
V
DD = 2.0 V
270 530
μ
A
VDD = 3.0 V 435 640
LV (Low-voltage
main) mode
Note 7
f
IH = 4 MHz
Note 4
V
DD = 2.0 V
435 640
μ
A
Square wave input 0.28 1.00
fMX = 20 MHz
Note 3
,
V
DD = 3.0 V
Resonator connection 0.45 1.17
mA
Square wave input 0.19 0.60
HS (high-speed
main) mode
Note 7
f
MX = 10 MHz
Note 3
,
V
DD = 3.0 V
Resonator connection 0.26 0.67
mA
Square wave input 95 330
fMX = 8 MHz
Note 3
,
V
DD = 3.0 V
Resonator connection 145 380
μ
A
Square wave input 95 330
LS (low-speed
main) mode
Note 7
f
MX = 8 MHz
Note 3
,
V
DD = 2.0 V
Resonator connection 145 380
μ
A
Square wave input 0.25 0.57
fSUB = 32.768 kHz
Note 5
TA = 40°C
Resonator connection 0.44 0.76
μ
A
Square wave input 0.30 0.57
fSUB = 32.768 kHz
Note 5
T
A = +25°C
Resonator connection 0.49 0.76
μ
A
Square wave input 0.38 1.17
fSUB = 32.768 kHz
Note 5
TA = +50°C
Resonator connection 0.57 1.36
μ
A
Square wave input 0.52 1.97
fSUB = 32.768 kHz
Note 5
TA = +70°C
Resonator connection 0.71 2.16
μ
A
Square wave input 0.97 3.37
IDD2
Note 2
HALT
mode
Subsystem
clock mode
f
SUB = 32.768 kHz
Note 5
TA = +85°C
Resonator connection 1.16 3.56
μ
A
TA = 40°C 0.16 0.50
TA = +25°C 0.23 0.50
TA = +50°C 0.34 1.10
TA = +70°C 0.46 1.90
Supply
current
Note 1
I
DD3
Note 6
STOP
mode
Note 8
T
A = +85°C 0.75 3.30
μ
A
(Notes and Remarks are listed on the next page.)