Renesas rl78 Answering Machine User Manual


  Open as PDF
of 1004
 
RL78/G1A CHAPTER 12 SERIAL ARRAY UNIT
R01UH0305EJ0200 Rev.2.00 500
Jul 04, 2013
Table 12-2. Selection of Operation Clock for 3-Wire Serial I/O
SMRmn
Register
SPSm Register Operation Clock (fMCK)
Note
CKSmn PRS
m13
PRS
m12
PRS
m11
PRS
m10
PRS
m03
PRS
m02
PRS
m01
PRS
m00
fCLK = 32 MHz
X X X X 0 0 0 0 fCLK 32 MHz
X X X X 0 0 0 1 fCLK/2 16 MHz
X X X X 0 0 1 0 fCLK/2
2
8 MHz
X X X X 0 0 1 1 fCLK/2
3
4 MHz
X X X X 0 1 0 0 fCLK/2
4
2 MHz
X X X X 0 1 0 1 fCLK/2
5
1 MHz
X X X X 0 1 1 0 fCLK/2
6
500 kHz
X X X X 0 1 1 1 fCLK/2
7
250 kHz
X X X X 1 0 0 0 fCLK/2
8
125 kHz
X X X X 1 0 0 1 fCLK/2
9
62.5 kHz
X X X X 1 0 1 0 fCLK/2
10
31.25 kHz
0
X X X X 1 0 1 1 f
CLK/2
11
15.63 kHz
X X X X 1 1 0 0 fCLK/2
12
7.81 kHz
X X X X 1 1 0 1 fCLK/2
13
3.91 kHz
X X X X 1 1 1 0 fCLK/2
14
1.95 kHz
X X X X 1 1 1 1 fCLK/2
15
977 Hz
0 0 0 0 X X X X fCLK 32 MHz
0 0 0 1 X X X X fCLK/2 16 MHz
0 0 1 0 X X X X fCLK/2
2
8 MHz
0 0 1 1 X X X X fCLK/2
3
4 MHz
0 1 0 0 X X X X fCLK/2
4
2 MHz
0 1 0 1 X X X X fCLK/2
5
1 MHz
0 1 1 0 X X X X fCLK/2
6
500 kHz
0 1 1 1 X X X X fCLK/2
7
250 kHz
1 0 0 0 X X X X fCLK/2
8
125 kHz
1 0 0 1 X X X X fCLK/2
9
62.5 kHz
1 0 1 0 X X X X fCLK/2
10
31.25 kHz
1
1 0 1 1 X X X X f
CLK/2
11
15.63 kHz
1 1 0 0 X X X X fCLK/2
12
7.81 kHz
1 1 0 1 X X X X fCLK/2
13
3.91 kHz
1 1 1 0 X X X X fCLK/2
14
1.95 kHz
1 1 1 1 X X X X fCLK/2
15
977 Hz
Other than above Setting prohibited
Note When changing the clock selected for f
CLK (by changing the system clock control register (CKC) value), do
so after having stopped (serial channel stop register m (STm) = 000FH) the operation of the serial array
unit (SAU).
Remarks 1. X: Don’t care
2. m: Unit number (m = 0, 1), n: Channel number (n = 0 to 3), mn = 00 to 03, 10, 11