RL78/G1A CHAPTER 6 TIMER ARRAY UNIT
R01UH0305EJ0200 Rev.2.00 224
Jul 04, 2013
6.5.2 Start timing of counter
Operation of timer count register mn (TCRmn) is enabled by setting of TSmn bit of timer channel start register m (TSm).
Operation from when counting is enabled to when timer count register mn (TCRmn) starts counting is shown in Table 6-6.
Table 6-6. Operations from Count Operation Enabled State to Timer count Register mn (TCRmn) Count Start
Timer operation mode Operation when TSmn = 1 is set
Interval timer mode
No operation is carried out from start trigger detection (TSmn=1) until count clock
generation.
The first count clock loads the value of the TDRmn register to the TCRmn
register and the subsequent count clock performs count down operation (see
6.5.3 (1) Operation of interval timer mode).
Event counter mode
Writing 1 to the TSmn bit loads the value of the TDRmn register to the TCRmn
register.
If detect edge of TImn input. The subsequent count clock performs count down
operation (see 6.5.3 (2) Operation of event counter mode).
Capture mode
No operation is carried out from start trigger detection (TSmn = 1) until count
clock generation.
The first count clock loads 0000H to the TCRmn register and the subsequent
count clock performs count up operation (see 6.5.3 (3) Operation of capture
mode (input pulse interval measurement)).
One-count mode
The waiting-for-start-trigger state is entered by writing 1 to the TSmn bit while the
timer is stopped (TEmn = 0).
No operation is carried out from start trigger detection until count clock
generation.
The first count clock loads the value of the TDRmn register to the TCRmn
register and the subsequent count clock performs count down operation (see
6.5.3 (4) Operation of one-count mode).
Capture & one-count mode
The waiting-for-start-trigger state is entered by writing 1 to the TSmn bit while the
timer is stopped (TEmn = 0).
No operation is carried out from start trigger detection until count clock
generation.
The first count clock loads 0000H to the TCRmn register and the subsequent
count clock performs count up operation (see 6.5.3 (5) Operation of capture &
one-count mode (high-level interval measurement)).