Renesas rl78 Answering Machine User Manual


  Open as PDF
of 1004
 
RL78/G1A CHAPTER 12 SERIAL ARRAY UNIT
R01UH0305EJ0200 Rev.2.00 467
Jul 04, 2013
12.5.4 Slave transmission
Slave transmission is that the RL78 microcontroller transmits data to another device in the state of a transfer clock
being input from another device.
3-Wire Serial I/O CSI00 CSI01 CSI10 CSI11 CSI20 CSI21
Target channel Channel 0 of
SAU0
Channel 1 of
SAU0
Channel 2 of
SAU0
Channel 3 of
SAU0
Channel 0 of
SAU1
Channel 1 of
SAU1
Pins used SCK00, SO00 SCK01, SO01 SCK10, SO10 SCK11, SO11 SCK20, SO20 SCK21, SO21
INTCSI00 INTCSI01 INTCSI10 INTCSI11 INTCSI20 INTCSI21 Interrupt
Transfer end interrupt (in single-transfer mode) or buffer empty interrupt (in continuous transfer mode)
can be selected.
Error detection flag Overrun error detection flag (OVFmn) only
Transfer data length 7 or 8 bits
Transfer rate Max. fMCK/6 [MHz]
Notes 1, 2
.
Data phase Selectable by the DAPmn bit of the SCRmn register
DAPmn = 0: Data output starts from the start of the operation of the serial clock.
DAPmn = 1: Data output starts half a clock before the start of the serial clock operation.
Clock phase Selectable by the CKPmn bit of the SCRmn register
CKPmn = 0: Forward
CKPmn = 1: Reverse
Data direction MSB or LSB first
Notes 1. Because the external serial clock input to the SCK00, SCK01, SCK10, SCK11, SCK20, and SCK21 pins is
sampled internally and used, the fastest transfer rate is f
MCK/6 [MHz].
2. Use this operation within a range that satisfies the conditions above and the peripheral functions
characteristic in the electrical specifications (see CHAPTER 29 ELECTRICAL SPECIFICATIONS (T
A = 40
to +85°C), CHAPTER 30 ELECTRICAL SPECIFICATIONS (G: INDUSTRIAL APPLICATIONS TA = 40 to
+105°C)).
Remarks 1. f
MCK: Operation clock frequency of target channel
2. m: Unit number (m = 0, 1), n: Channel number (n = 0 to 3), mn = 00 to 03, 10, 11
<R>