CHAPTER 30 ELECTRICAL SPECIFICATIONS (G: INDUSTRIAL APPLICATIONS T
A
=
40 to +105
°
C)
R01UH0305EJ0200 Rev.2.00 915
Jul 04, 2013
30.3.2 Supply current characteristics
(TA = 40 to +105°C, 2.4 V EVDD0 VDD 3.6 V, VSS = EVSS0 = 0 V) (1/3)
Parameter Symbol Conditions MIN. TYP. MAX. Unit
Basic
operation
VDD = 3.0 V 2.1 mAfIH = 32 MHz
Note 3
Normal
operation
V
DD = 3.0 V 4.6 7.5 mA
fIH = 24 MHz
Note 3
Normal
operation
VDD = 3.0 V 3.7 5.8 mA
HS (high-speed
main) mode
Note 5
f
IH = 16 MHz
Note 3
Normal
operation
VDD = 3.0 V 2.7 4.2 mA
Square
wave input
3.0 4.9 fMX = 20 MHz
Note 2
,
V
DD = 3.0 V
Normal
operation
Resonator
connection
3.2 5.0
mA
Square
wave input
1.9 2.9
HS (high-speed
main) mode
Note 5
f
MX = 10 MHz
Note 2
,
V
DD = 3.0 V
Normal
operation
Resonator
connection
1.9 2.9
mA
Square
wave input
4.1 4.9 fSUB = 32.768 kHz
Note 4
TA = 40°C
Normal
operation
Resonator
connection
4.2 5.0
μ
A
Square
wave input
4.2 4.9 fSUB = 32.768 kHz
Note 4
TA = +25°C
Normal
operation
Resonator
connection
4.3 5.0
μ
A
Square
wave input
4.3 5.5 fSUB = 32.768 kHz
Note 4
TA = +50°C
Normal
operation
Resonator
connection
4.4 5.6
μ
A
Square
wave input
4.5 6.3 fSUB = 32.768 kHz
Note 4
TA = +70°C
Normal
operation
Resonator
connection
4.6 6.4
μ
A
Square
wave input
4.8 7.7 fSUB = 32.768 kHz
Note 4
TA = +85°C
Normal
operation
Resonator
connection
4.9 7.8
μ
A
Square
wave input
6.9 19.7
Supply
current
IDD1
Note 1
Operating
mode
Subsystem
clock mode
f
SUB = 32.768 kHz
Note 4
TA = +105°C
Normal
operation
Resonator
connection
7.0 19.8
μ
A