Renesas rl78 Answering Machine User Manual


  Open as PDF
of 1004
 
RL78/G1A CHAPTER 11 A/D CONVERTER
R01UH0305EJ0200 Rev.2.00 376
Jul 04, 2013
11.6.5 Hardware trigger no-wait mode (select mode, sequential conversion mode)
<1> In the stop status, the ADCE bit of A/D converter mode register 0 (ADM0) is set to 1, and the system enters the
A/D conversion standby status.
<2> After the software counts up to the stabilization wait time
Note
, the ADCS bit of the ADM0 register is set to 1 to
place the system in the hardware trigger standby status (and conversion does not start at this stage). Note that,
while in this status, A/D conversion does not start even if ADCS is set to 1.
<3> If a hardware trigger is input while ADCS = 1, A/D conversion is performed on the analog input specified by the
analog input channel specification register (ADS).
<4> When A/D conversion ends, the conversion result is stored in the A/D conversion result register (ADCR, ADCRH),
and the A/D conversion end interrupt request signal (INTAD) is generated. After A/D conversion ends, the next
A/D conversion immediately starts.
<5> If a hardware trigger is input during conversion operation, the current A/D conversion is interrupted, and
conversion restarts. The partially converted data is discarded.
<6> When the value of the ADS register is rewritten or overwritten during conversion operation, the current A/D
conversion is interrupted, and A/D conversion is performed on the analog input respecified by the ADS register.
The partially converted data is discarded.
<7> When ADCS is overwritten with 1 during conversion operation, the current A/D conversion is interrupted, and
conversion restarts. The partially converted data is discarded.
<8> When ADCS is cleared to 0 during conversion operation, the current A/D conversion is interrupted, and the
system enters the A/D conversion standby status. However, the A/D converter does not stop in this status.
<9> When ADCE is cleared to 0 while in the A/D conversion standby status, the A/D converter enters the stop status.
When ADCS = 0, inputting a hardware trigger is ignored and A/D conversion does not start.
Note If a high-accuracy channel is selected as the analog input channel: Stabilization wait time = 0.5
μ
s
If a standard channel is selected as the analog input channel: Stabilization wait time = 2
μ
s
Figure 11-21. Example of Hardware Trigger No-Wait Mode (Select Mode, Sequential Conversion Mode)
Operation Timing
ADCE is set to 1.
<1>
ADCS is set to 1.
<2>
A hardware trigger
is generated.
<3>
A hardware trigger is
generated during A/D
conversion operation.
<5>
A/D conversion
ends and the next
conversion
starts.
<4>
ADS is rewritten during
A/D conversion operation
(from ANI0 to ANI1).
<6>
Conversion is
interrupted
and restarts.
Conversion is
interrupted
and restarts.
Conversion is
interrupted and
restarts.
<4> <4> <4>
<4>
ADCS is overwritten
with 1 during A/D
conversion operation.
<7>
ADCS is cleared
to 0 during A/D
conversion operation.
ADCE is cleared to 0.
<9>
ADCE
ADCS
ADS
INTAD
ADCR,
ADCRH
A/D
conversion
status
Hardware
trigger
Stop
status
ANI0 ANI1
The trigger is not
acknowledged.
Trigger
standby
status
The trigger is not
acknowledged.
Data 1
(ANI0)
Data 1
(ANI0)
Data 2
(ANI0)
Data 4
(ANI0)
Data 2
(ANI0)
Data 3
(ANI0)
Data 4
(ANI0)
Data 5
(ANI0)
Data 6
(ANI1)
Data 6
(ANI1)
Data 8
(ANI1)
Data 7
(ANI1)
Data 8
(ANI1)
Data 8
(ANI1)
Conversion
standby
Conversion
standby
Stop
status
Conversion
is interrupted.
<8>