RL78/G1A CHAPTER 6 TIMER ARRAY UNIT
R01UH0305EJ0200 Rev.2.00 225
Jul 04, 2013
6.5.3 Operation of counter
Here, the counter operation in each mode is explained.
(1) Operation of interval timer mode
<1> Operation is enabled (TEmn = 1) by writing 1 to the TSmn bit. Timer count register mn (TCRmn) holds the
initial value until count clock generation.
<2> A start trigger is generated at the first count clock after operation is enabled.
<3> When the MDmn0 bit is set to 1, INTTMmn is generated by the start trigger.
<4> By the first count clock after the operation enable, the value of timer data register mn (TDRmn) is loaded to the
TCRmn register and counting starts in the interval timer mode.
<5> When the TCRmn register counts down and its count value is 0000H, INTTMmn is generated and the value of
timer data register mn (TDRmn) is loaded to the TCRmn register and counting keeps on.
Figure 6-25. Operation Timing (In Interval Timer Mode)
Caution In the operation in the first count clock cycle after writing the TSmn bit, an error at a maximum of
one count clock cycle occurs since count start delays until count clock has been generated.
When the information on count start timing is necessary, an interrupt can be generated when
counting is started by setting MDmn0 = 1.
Remarks 1. f
MCK, the start trigger detection signal, and INTTMmn become active between one clock in
synchronization with fCLK.
2. m: Unit number (m = 0), n: Channel number (n = 0 to 7 (however, timer input pin (TImn), timer output
pin (TOmn) : n = 0, 1, 3 to 7))
fMCK
(fTCLK)
m
TSmn (write)
TEmn
Start trigger
detection signal
TCRmn
Initial
value
m
TDRmn
INTTMmn
When MDmn0 = 1 setting
<1>
<3>
<4>
m1
0000
m
0001
<2>
<5>