RL78/G1A CHAPTER 12 SERIAL ARRAY UNIT
R01UH0305EJ0200 Rev.2.00 493
Jul 04, 2013
(4) Processing flow (in continuous transmission/reception mode)
Figure 12-68. Timing Chart of Slave Transmission/Reception (in Continuous Transmission/Reception Mode)
(Type 1: DAPmn = 0, CKPmn = 0)
SSmn
SEmn
SDRmn
SCKp pin
SIp pin
INTCSIp
TSFmn
Write
Write
SOp pin
BFFmn
<8>
Write
MDmn0
STmn
Transmit data 1 Transmit data 2 Transmit data 3Receive data 1 Receive data 2
Receive data 3
Receive data 1 Receive data 2
Receive data 3
Transmit data 1
Transmit data 2 Transmit data 3
Data transmission/reception
Data transmission/reception
Data transmission/reception
<1>
<2> <2> <2><3> <3> <3><4> <4>
<5>
<6> <7>
Note 1
Note 2
Note 2
Read
Read
Read
Reception & shift operation
Reception & shift operation
Reception & shift operation
Shift
register mn
Notes 1. If transmit data is written to the SDRmn register while the BFFmn bit of serial status register mn
(SSRmn) is 1 (valid data is stored in serial data register mn (SDRmn)), the transmit data is overwritten.
2. The transmit data can be read by reading the SDRmn register during this period. At this time, the
transfer operation is not affected.
Caution The MDmn0 bit of serial mode register mn (SMRmn) can be rewritten even during operation.
However, rewrite it before transfer of the last bit is started, so that it has been rewritten before the
transfer end interrupt of the last transmit data.
Remarks 1. <1> to <8> in the figure correspond to <1> to <8> in Figure 12-69 Flowchart of Slave
Transmission/Reception (in Continuous Transmission/Reception Mode).
2. m: Unit number (m = 0, 1), n: Channel number (n = 0 to 3), p: CSI number (p = 00, 01, 10, 11, 20, 21),
mn = 00 to 03, 10, 11
<R>
<R>