Nortel Networks BCM200/400 Telephone User Manual


 
Media Bay Module Combinations 347
Installation and Maintenance Guide
Table 70 demonstrates either a full double density system or a partial double density system
because DS30 06 and 07 have trunk modules installed. Double density only affects system
modules.
Table 70 All station modules set for double density
DS30
channel
#
Each heavily-outlined and shaded square represents one
module. Switch setting
1
DSM 32+
Offset 0
1
DSM 16+
Offset 0
2
ASM 8s
Offset 0 and 1
2
DTMs
Offset 0 123456
2
0 DSM 32+ settings: offononononon
3
0 DSM 32+ settings: offononononoff
4
0 DSM 16+ settings: offonononoff on
0 DSM 16+ settings: off on off on off on
5 0 ASM8 settings: ononononoff on
1 ASM8 settings: on on off on off on
0 ASM8 settings: on off on on off on
1 ASM8 settings: on off off on off on
6
0 onononoff on on
7
0 onononoff on off