Nortel Networks BCM200/400 Telephone User Manual


 
Chapter 12 Install Companion or DECT Systems 263
Installation and Maintenance Guide
The polarity of the TCM connections is not important. If you connect the two power pairs to
the bracket terminal board of the base station, you must connect the power pairs with the same
polarity.
5 Install the base station on the bracket. Snap it into position.
6 Connect the power RJ-11 jumper lead to the RJ-11 jacks on the termination board and the base
station.
7 For plug top power supplies only, connect the power supply connector to the base station
power connector. Make sure the base station uses a class 2 plug top power source only.
8 In the space provided on the label attached to the lower right corner of the mounting bracket,
record the port number used.
Include the marking information for all of the base stations on the completed installation floor
plans.
9 Slide the cover on the bracket, using the guide to position it correctly. Refer to Figure 169.
Figure 169 Slide the cover on bracket
10 Snap the cover into place.
11 This procedure is complete.
Caution: Ensure that the RPI is off before connecting power pairs to the base station.
Caution: If you insert the power supply connector in the wrong direction, you can
damage the plug top power supply and the base stations.
Position the power supply connector in the correct direction and push it into place.