Nortel Networks BCM200/400 Telephone User Manual


 
Telephony Hardware Selection and Settings 341
Installation and Maintenance Guide
DSM16/DSM 32 single density switch settings (new 3.0 system)
The following table shows the switch settings for DSM modules deployed as single density on a
new 3.0 system.
Note that Companion sets can only be assigned on DS30 6 and 7, and the handsets have a different
set of default DNs than the digital sets. Also, Companion can only be deployed on systems that
remain at Part Double Density (PDD), the default condition of 3.0 systems.
Note: DSM modules deployed prior to 3.0 are all single density and cannot be set to
double density, but they can still be used on new 3.0 systems. The DSM 16+ and DSM32+
modules can be set to either density.
Table 64 DSM 16/DSM 16+ and DSM 32/DSM32+ single density switch settings for new 3.0 systems
Select
DS30
bus
Enter these switch
settings
**To
assign
these DNs
to
DSM 16
or DSM 16+
To assign these
DNs to DSM 32 or
DSM 32+
Top Bottom
To assign these DNs
to Companion
1 2 3 456
2
on on on on on on
221-236 253-268 221-236
N/A
3
on on on on on off
253-268 285-300 253-268
4
on on on on off on
285-300 317-332 285-300
5
on on on on off off
317-332 349-364 317-332
6
on on on off on on
349-364 381-396 349-364
565-580**** (PDD
only)
***7
on on on off on off
381-396 N/A
581-596**** (PDD
only)
**The extensions listed are based on a three-digit DN with a Start DN of 221. If your system has longer DNs or a
different Start DN, enter the range in the blank column.
***If your system is configured with a 3/5 channel split, you cannot use DS30 7 for the DSM 16 module. You cannot
configure the DSM32 module for DS30 6 because the second set of DNs cannot be accessed.
****If you need more DNs for Companion sets, use the range that starts at 597 (ISDN or DECT) and change the
DN type to NA Portable.
*****If you system is set to Full Double Density (FDD), Companion telephones are not supported.