176 Chapter 7 Hard Disk Replacement Procedures
P0993133 03
8 Slide the advanced function tray completely into the BCM400 platform base chassis (see
“Install the advanced function tray” on page 159).
9 Restore the Business Communications Manager to operation. Refer to “Restart the System
after Maintenance” on page 147.
10 Set up the hard disk:
a Initialize the hard disk. Refer to “Initialize the Hard Disk” on page 176.
b After the disk is initialized, restore your data from your backups. If you did not backup
your keycodes, re-enter them.
11 This procedure is complete.
Initialize the Hard Disk
The Business Communications Manager system is normally initialized prior to shipment.
However, if you have to replace the hard drive in a Business Communications Manager, you must
re-initialize the Business Communications Manager.
After you replace the hard disk and the system has booted up, perform the initialization as follows:
1 Make sure the Status LED on the Business Communications Manager is lit. This LED that all
services have started and the Business Communications Manager is operating correctly.
2 Attach the base function tray and a computer through the serial port, as described in “Null
modem cable setup” on page 138.
3 Enter the terminal emulation program, as described in “Display the configuration menus” on
page 139,
If the hard disk does not require initialization, the main menu appears. Refer to Figure 102.