Nortel Networks BCM200/400 Telephone User Manual


 
Chapter 6 Prepare Hardware for Maintenance or Upgrades 145
Installation and Maintenance Guide
Special Tools
Before you replace the components, ensure you have the following equipment:
Phillips screwdriver #2, with a blade 3.5 in. long
3/16 inch slot screwdriver
antistatic wrist grounding strap
Controlled System Shutdown
Use the procedures described in this section to perform a controlled software and hardware system
shutdown.
The Business Communications Manager system requires a controlled shutdown to guarantee the
integrity of the file system. The procedures in this section assume you have access to the Unified
Manager.
If a controlled shutdown is not possible, disconnect the power cord from the AC power outlet
power-down the Business Communications Manager.
Shut down the system software
Use this procedure to ensure a safe shutdown of the Business Communications Manager software
system.
1 Start a web browser on a computer with a LAN connection to the Business Communications
Manager system.
2 Enter the IP address of the Business Communications Manager system and the port number
for Business Communications Manager Unified Manager (:6800). For example: http://
10.10.10.1:6800.
3 Click the Configure button.
4 Type your user name in the Login box. The default user name is supervisor.
5 Type your password in the Password box. The default password is visor.
6 Choose System.
7 Click the Logoff menu and then click Shutdown.
8 Click the Yes button.
9 Wait until the Status changes to Complete! It is safe to turn off the system.
Caution: You must wear an antistatic grounding strap at all times when handling
electronic components. Failure to do so can result in damage to the equipment.