Nortel Networks BCM200/400 Telephone User Manual


 
Chapter 6 Prepare Hardware for Maintenance or Upgrades 147
Installation and Maintenance Guide
Restart the System after Maintenance
When you finish your power-off maintenance procedure, restart the Business Communications
Manager system in the order described in this section.
Restore the System to Operation
To restore the system to operation after maintenance activities, follow these steps:
1 Ensure that all cables inside the housing are connected snuggly to the correct boards and
excess cable bundled neatly, out of the way.
2 Replace the bezel on the Business Communications Manager platform base chassis, if you
removed it.
3 Replace the platform base chassis top cover and replace the screws.
4 If you removed the Business Communications Manager from the rack or wall, replace it.
5 Plug the expansion unit, if there is one, into the AC power source.
6 Plug the Business Communications Manager into the AC power source.
The Business Communications Manager automatically starts booting.
7 Replace all the connectors to the front of the units. The reboot can take several minutes to
complete.
8 This procedure is complete.
Software Restart
Use this procedure to perform a software reboot. If you did not shut the system power down,
restart the software.
1 Refer to “Shut down the system software” until you get to step 7.
2 At this point, select Reboot on the Logoff menu.
3 Continue with the intructions shown on the display terminal.
4 This procedure is complete.
Warning: When you restart the system, all IP clients/voice mail and VoIP ports are not
available until the system services restart.