178 Chapter 7 Hard Disk Replacement Procedures
P0993133 03
4 Enter the number beside the upload for the software you want to install. If you do not know
which software to upload, refer to “Core Software and Regions” on page 299.
5 Ensure the correct MSC configuration has been entered.
Enter 1 (Select the hardware profile for this unit).
6 The current MSC configuration is indicated on screen.
If you want to change this, make a different selection from the Platform Initialization
menu. The system checks to see if a core upload is required. This takes about 10 minutes.
If you do not want to change the MSC load, enter the number of the selection with the
asterisks.
7 The system automatically reboots a number of times as part of the initialization process. When
the first reboot occurs, the telnet session disconnects.
8 Do one of the following:
Run the Quick Start Wizard to create the system parameters and defaults. Then restore your
system data from your data backup.
Restore system and data information from your backup data.
9 This procedure is complete.
Note: The detailed processes for performing steps 6 and 7 are contained in the Business
Communications Manager 3.0 Programming Operations Guide.