Nortel Networks BCM200/400 Telephone User Manual


 
124 Chapter 4 Install, remove or replace the Media Bay Modules
P0993133 03
Configure and register the handsets according to the instructions provided for each type of
system.
Companion: Programming Operations Guide
—DECT: DECT Installation and Maintenance Guide
T7406: T7406 Cordless Handset Installation Guide
NetVision and NetVision data: IP Telephony Configuration Guide
5 This procedure is complete.
FEM Wiring
A Fiber Expansion module (FEM) allows you to upgrade from a Norstar system to a Business
Communications Manager system by reusing the Norstar expansion modules. The expansion
modules connect to the FEM module using the same fiber cable that connected them to the Norstar
fiber expansion card.
Warning: Handling optical fiber cables:
If the cable is too long, ensure that it is coiled correctly using the fiber spool.
Coil excess fiber cable carefully around the spool provided. Do not bend the cable around
any tight corners. Bends in the fiber cable must not be less than 100 mm in diameter. Place
the fiber cable spool into a slot at the back of the cable trough in the Norstar module.
Note: If you enable all six jacks of the FEM module, the FEM module is the only module
you can install on your Business Communications Manager system, because each port
requires one DS30 channel. Refer to “FEM switch settings” on page 344.