Nortel Networks BCM200/400 Telephone User Manual


 
342 Telephony Hardware Selection and Settings
P0993133 03
DSM16+ and DSM 32+ double density switch settings (new 3.0 system)
The following table shows the switch settings for DSM-plus modules deployed as double density
on a new 3.0 system.
Companion has not be included in this table because you cannot use double density modules to
deploy Companion.
Note: DSM modules deployed prior to 3.0 are all single density and cannot be set to
double density, but they can still be used on new 3.0 systems. The DSM 16+ and DSM32+
modules can be set to either density.
Table 65 DSM 16+ and DSM32+ double density switch settings for new 3.0 systems
Select
DS30
bus
Enter these switch settings
To assign these
DNs
to
DSM 16+:
A= DSM1, B=DSM2
To assign these DNs to
DSM 32+ (connectors:
A=top, B = bottom)
123456
2
off on on on on on A
221-236 A 237-252
off on off on on on B
237-252 B 221-236
3
off on on on on off A
253-268 A 269-284
off on off on on off B
269-284 B 253-268
4
off on on on off on A
285-300 A 301-316
off on off on off on B
301-316 B 285-300
5
off on on on off off A
317-332 A 333-348
off on off on off off B
333-348 B 317-332
6
off on on off on on A
349-364 A 365-380****
off on off off on on B
365-380**** B 349-364
***7
off on on off on off A
381-396 A 397-412*****
off on off off on off B
397-412***** B 381-396
**The extensions listed are based on a three-digit DN with a Start DN of 221. If your system has longer DNs or a
different Start DN, enter the range in the blank column.
***If your system is configured with a 3/5 channel split, you cannot use DS30 7.
****Available only on systems set to FDD. Modules cannot be set to double density on systems set to PDD. Refer to
the previous chart for the switch settings for single density and PDD.
*****Available only on systems set to FDD, with a 2/6 DS30 split. Modules cannot be set to double density on
systems set to PDD. Refer to the previous chart for the switch settings for single density and PDD.