Fujitsu MB89950/950A Pager User Manual


 
253
CHAPTER 12 LCD CONTROLLER/DRIVER
LCD panel connections and display data example (1/2 duty ratio drive mode)
Figure 12.4-3 Segment/common connections, data states and corresponding display
COM1
COM0
SEGn+3
SEGn+2
SEGn+1
SEGn
*
7
*
0
*
5
*
4
*
2
*
6
*
1
*
3
SEG0
SEG1
SEG2
SEG3
SEG4
SEG5
SEG6
SEG7
SEG8
SEG9
SEG10
SEG11
COM3
––
––
––
––
––
––
––
––
––
––
––
––
COM2
––
––
––
––
––
––
––
––
––
––
––
––
COM1
0
1
1
1
0
0
1
1
1
1
0
1
COM0
1
1
1
1
0
0
1
0
0
1
1
1
064
H
065H
066H
067H
068H
069H
LCD Panel
Display RAM
Address
Segment No.
*0 to *7: Indicate corresponding display RAM bits. (Bits 2, 3, 6, and
7 are not used.)
Address COM3 COM2 COM1 COM0
nH bit3 bit2
bit1
*1
bit0
*0
SEGn
bit7 bit6
bit5
*3
bit4
*2
SEGn+1
n+1H bit3 bit2
bit1
*5
bit0
*4
SEGn+2
bit7 bit6
bit5
*7
bit4
*6
SEGn+3
0: OFF
1: ON
Address COM3 COM2 COM1 COM0
064H ——11SEG0
——10SEG1
065H ——10SEG2
——01SEG3
LCD
Display
Bit States for Numerals "0" through "9"
bit7 bit6 bit5 bit4 bit3 bit2 bit1 bit0
—— 11——01
—— 11——11
—— 00——00
—— 10——11
—— 11——10
—— 11——01
—— 11——10
—— 11——11
—— 00——11
—— 10——11
—— 10——11
—— 01——11
—— 11——11
—— 01——11
—— 00——01
—— 11——11
—— 11——11
—— 11——11
—— 10——11
—— 11——11
Example) Using segments to represent "5".