Fujitsu MB89950/950A Pager User Manual


 
167
CHAPTER 8 PULSE WIDTH COUNT TIMER (PWC)
Program example 2 for interval timer function (one-shot timer mode)
Processing description
Generates a single 1.5 ms interval timer interrupt (one-shot timer mode).
The TO bit is initialized to "1" and inverted after the interval time.
The following shows the RLBR register value that results in an interval time of approximately 3 ms for
a 5 MHz main clock oscillation frequency. The count clock is 32 t
inst
(t
inst
: Instruction cycle).
RLBR register value = 3 ms/(32 x 4/5 MHz) = 117.2 (075
H
)