PROGRAMMINGPROCEDURES-INSTRUCTIONS/SYSTEMRECOROS
SECTION 200-096-302
FEBRUARY1991
PROGRAM03
FLEXIBLEPCBSLOTASSIGNMENTS
To Store Data ,*
~-~~~~~~~~~n-nln-n-r;?-n-~
CARD = PCB Code
See Note 6.
See Reference Table
DK24156
SLOT NO. 00 01
NOTES:
DK24. slots 00 - Ofi on/v
PCTUS, ports 00 - 23
PCTU(2), ports 00 - 96
PCTU(3), ports 00 - 96
I
,
I
1 w/DSS
1. See instructions in Table 1-E (Section 200-096-301) to input the data from this record.
2. Shaded rows on tables are for configuration purposes only,
3. A PCTU (PCB codes 91, 92 or 93) must be installed in slot 00 (labeled PCTU).
4. A PEKU , PESU or PDKU is always installed in slot 01.
5. Initialized data reads slot 00 = 91, slot 01 = 21, slots 02 - 14 = 00.
6. System PCB slots are labeled PCTU, SO1 - S14. For programming, these tables label the
same slots 00 (PCTU) - 14.
7. PESU circuits: 1 and 2, standard telephones; 3 and 4, not used; 5 - 8, electronic telephones.
Total 8 station ports used in software; available with Release 2, and above.
8. PCTUl, PCTU2, PCTU3 (PCTUS in DK24 only).
9. PCTUl, PCTlJ2 orPCTlJ3only.
10. OCA or PDIU-DI/PDIU-DS is not available with slots 11 - 14.
11. PDIU-DI/PDIU-DS will function with either PDKU code 62 or 64; a special code is not
required (Release 3).
12. System Power must always be cycled after running Program 03.
13. PCTlJ3 is required when a PDKU is installed.
I