Toshiba DK56 Telephone User Manual


 
INSTALLATION-CONFIGURATION
SECTION 200-096-204
FEBRUARY 1991
I
I
I
I
I
I
I
I
I
I
CONFIGURATION GUIDE, WORKSHEET 5
F. System and Slot Check
.
1. Add total PCB/slot requirements (from Worksheets 2 N 4): AT + AAT+ BTl + BT2 + CT + DT + ET
=
total. PCB/slot
IMPORTANT NOTE!
One or two additional slots should always be considered for future growth.
2. If total is six or less, use
DK24
and
PCTUSl
with the following considerations:
a. Total PEKU/PSTU/PESU PCBs combined: three or less (no PEMU equipped).
b. Total PEKU/PSTU/PESU PCBs combined: two or less (PEMU equipped).
c. Total PCOU PCBs:.four or less.
d. Total PEMU PCBs: one or less.
DK24 with PCTUS
e. DSS consoles: three or less.
f. HDCB controllers: three or less.
g. If using 2000~/3000-/6000-/6005series electronic telephones and/or a PEMU, use Power
Check, Worksheet 7.
3. if total is six or less, use
DK24
and
PCTU (1,
2, or 3) with the following considerations:
a. Total PDKU/PEKU/PSTU/PESU PCBs combined: four or less (no PEMU equipped).
b. Total PDKU/PEKU/PSTU/PESU PCBs combined: three or less (PEMU equipped).
c. Total PCOU PCBs: six or less.
d. Total PEMU PCBs: one or less.
DK24 with PCTUl , 2, or 3
e. Combined DDSS and DSS consoles: four or less.
f. HDCB controllers: four or less.
g. If using 2000-/3000-/6000-/6005series electronic telephones, PDIU-Dls, and/or a PEMU, use
Power Check, Worksheet 7.
4. If total is eight or less, use
DK56
and
PCTU (1,
2, or 3) with the following considerations:
a. PDKU/PEKU/PSTU/PESU PCBs combined: eight or less.
b. PCOU PCBs: eight or less.
c. PEMU PCBs: two or less.
d. PEMU and PCOU: eight or less.
DK56 with PCTUI, 2, or 3
e. Combined DDSS and DSS consoles: four or less.
f. HDCB controllers: four or less.
g. If using 2000-/3000-/6000-/6005-series electronic telephones, PDIU-Dls, and/or a PEMU, use
Power Check, Worksheet 7.
5. If this total is above eight, use
DK96
and
PCTU (1,
2, or 3) with the following considerations:
a. PDKU/PEKU/PSTU/PESU PCBs combined: 12 or less.
b. PCOU PCBs: nine or less.
c. PEMU PCBs: three or less
d. PEMU and PCOU: nine or less. DK96 with PCTUl , 2, or 3
e. Combined DDSS and DSS consoles: four or less.
f. HDCB controllers: four or less.
g. If using 2000-/3000-/6000-/6005-series electronic telephones, PDIU-Dls, and/or a PEMU, use
Power Check, Worksheet 7.
I
NOTE:
PDKU and DDSS rewire PCTU3.
4-14