Toshiba DK56 Telephone User Manual


 
7.03 System Program Data Printout.
If a printer
is connected to the SMDR port, customer program
information stored in the PCTU or PCTUSI RAM
may be printed out for reference by using
Program
97 (see Paragraph 7.14).
7.10 SMDR Hardware Requirements
7.11
A DK system must be equipped with a PIOU
or PIOUS PC6 to support the SMDR printer/call
accounting device option. Connection of the printer
or call accounting device to the PIOU or PIOUS
PCB is accomplished with a 3-pair modular cord (7
feet maximum) and a PPTC connector adaptor
(refer to Figure 8-19 for details). Call record data is
ASCII-formatted, 8 bits, no parity, 1 -stop bit.
7.12 The PIOU or PIOUS contains a call record
buffer which stores call record data (for up to 50
calls) when the printed or call accounting device is
turned off, or when no device is connected to the
SMDR port. No further call records are stored after
the buffer is filled. When the printer or call account-
ing device is made operational, an “ERROR
BUFFER OVERFLOW” message is printed to indi-
cate that the buffer was full, and that some call
information may have been lost.
7.13 SMDR Programming Considerations
7.14 SelectableprogrammingoptionsfortheSMDR
printer or call accounting device are:
Program 60
l
Item 3-Selects the records of outgoing calls or
outgoing and incoming calls to be printed.
l
Item 4-Selects digit length of account code (4 to
15 digits).
l
Item 5-Allows only long distance call records to
be printed.
Program 97
l
Allows system program data to be printed via the
SMDR port (refer to Figure 8-20 for an example
printout).
NOTES:
1. An SMDR printer must be connected to
the SMDR port to use the printout option
selected by Program 97.
2. Call record data is lost when program data
is printed out using
Program 97.
INSTALLATION-PERIPHERALS
SECTION 200-096-208
FEBRUARY 1991
7.20 SMDR Printer/Call Accounting Device In-
stallation
7.21 Install the SMDR printer/call accounting de-
vice option in accordance with the following steps
(refer to Figures 8-19, 9-l 7, and 9-l 9):
1)
2)
3)
4)
Connect the interface cable and the PPTC
adaptor from the PIOU or PIOUS SMDR port
to the SMDR printer or call accounting device
DB25 connector.
Set the PIOU or PIOUS
SW1
switch to the
appropriate baud rate (300 or 1200 bps), as
determined by the baud rate of the printer or
call accounting device.
Set the printer or call accounting device to 8-
bits/no parity/one stop bit.
Program
(Program 60)
the system for the re-
quired SMDR printer/call accounting device
options (refer to Paragraph 7.13 and the Pro-
gramming Procedures, Section 200-096-300).
8 MAINTENANCE TERMINAL OPTIONS
8.00 A customer-supplied maintenance terminal
may be connected to the system (PIOU or PIOUS)
either locally or remotely. The maintenance termi-
nal (ASCII terminal) allows system programming
and testing to be accomplished. Also, the IMDU
modem or an external maintenance modem (300 or
1200 baud full-duplex) can be connected to allow
system programming and testing to be accom-
plished from a remote location.
NOTE:
An external modem is required for Remote
Maintenance if an IMDU is not installed on the
PIOU or PIOUS. The IMDU has a built-in
maintenance channel for remote connection;
however, an external modem requires a CO
line, PSTU or PESU port.
8.10 Maintenance Terminal/External Modem
Option System Hardware Requirements
8.11
The STRATA DK system must be equipped
with a PIOU or PIOUS PCB to support the mainte-
nance terminal/external modem options. Connect-
ing the maintenance terminal or external mainte-
8-13