Toshiba DK56 Telephone User Manual


 
PROGRAMMINGPROCEDURES-INSTRUCTIONS/SYSTEMRECORDS
SECTION 200-096-302
FEBRUARY1991
Restriction Class can be assigned with
Program 70 to each of the 300 Verified
Account Codes.
l
Verified Account Code Dial Require-
ment (Release 3)-Verified Account Code
Dial Requirement is assigned on a station-
by-station basis in Program 30, LED 140N.
All Account Codes dialed (forced or volun-
tary) from stations assigned in this pro-
gram will be verified.
l
Code Change-Stations selected in Pro-
gram 30, LED 15 ON, can change Verified
Account Codes (VAC) by dialing the
following:
~+~~~+ono-ooo+VAC+~or~
l
Verified Account Codes: Forced/Volun-
tary Program Options (Release 3)-Any
station can dial a Voluntary Account Code
after accessing a CO line ( 0
F
11; or,
with Release 3, dial 1 1 @ or press the
B button). Forced Account Code
requirements are assigned via station and
CO line program options: stations are as-
signed in Program 30, LED 08 ON; and
CO lines are assigned in Program 15-7.
Stations must dial Verified Account Codes
when assigned in Program 30, LED 14 ON.
Program 70-Verified Account Code Toll Re-
striction Assignments (Release 3): A Toll
Restriction Class can be assigned with this
program to each of the 300 Verified Account
Codes assigned in Program 69. Therefore,
when a Forced Verified Account Code is dialed
at a station, the station temporarily assumes
the toll restriction class assigned to the Verified
Account Code. When Program 70 is initial-
ized, all Verified Account Codes are assigned
as not toll restricted (data = 00). Verified Ac-
count Code Toll Restriction class assignments
are not user programmable; so if the assign-
ments are not known, it is recommended to
assign a number (block) of Verified Account
Codes to each type of toll restriction class. For
example:
VACs 000 - 050 = no restriction
VACs 051 - 100 = total restriction
VACs 101 - 150 = Class 1
etc.
Program 77-I-Peripheral Options:
l
Door LockTime, LED 20-The Door Lock
relay contact may be programmed to’oper-
ate for either 3 or 6 seconds (applies to
PIOU, PIOUS, PEPU, and HDCB door lock
controls).
l
PEKU Port Number/HDCB, LEDs 16 -
1 g--Door phone/lock existence is defined
by this program. Door phone/lock control-
lers (HDCB) can only exist at ports 04, 12,
20 and 28, and can only be installed on the
5th circuit of a PEKU and/or PESU. After
assignment of an HDCB, door phone num-
bers (151 - 159, 161 - 163) will effectively
replace the station number assignment in
Program 04. The door lock option is set via
Program 77-2.
NOTE:
HDCB4, port28, is not available with PCTUS.
l
IMDU Modem, LED 14-Informs the soft-
ware that an internal Remote Maintenance
modem (IMDU) is installed. Its station
number is 19 (unless the access code
prefix has been changed with Program05).
l
Night Ringing over External PageZones,
LEDs 10 - 13 (Release 3): For each ex-
ternal paging zone, Tenant 1 or Tenant 2
CO lines can be selected with this program
to night ring. For this feature to work, the
appropriate CO lines must be programmed
to night ring overexternal page in Program
78. Tenant assignments are made in
Program 15.
NOTE:
The PIOU option PCB must be installed to
allow this option.
l
Door Phone Ring On External Page,
LED08-If adoor phone button is pressed,
a ring tone can be enabled or disabled to
external paging when the system is in night
mode. Activation of a m button is re-
quired to activate this feature. The m
does not apply to door phones.
l
Door Lock Relay/External Page Relay,
LED 07-A relay on the PIOU, PIOUS or
2-17