PROGRAMMING PROCEDURES-INTRODUCTION
SECTION 200-096-301
FEBRUARY1991
TABLEI-F
PROGRAM00
SOFTWARECHECKANDREMOTEMAINTENANCESECURITYCODEASSIGNMENTS
Press...
Step
w + LED keys
ti
Action description
LCD RESPONSE . . .
I
1.
Use the programming LCD electronic or digital telephone
NO. 205
with programming template connected to port 05 - circuit 6.
JAN
20 SUN
06:43
2. mElWEB
PROGRAM MODE
Enter programming mode.
3. =Iim
PROGRAM = 00
Speaker beeps to indicate when to enter program
DATA STORE
number. Access Program 00.
4. m
00 SELECT =
Prepare system for a selection.
5.
Select one of the following attributes:
A. 1 00 SELECT = 0
View the software version. This attribute is not editable.
l
DXnn= PCTUl OR PCTU2 VERSION
OR
l
DVno= PCTUS VERSION
l
PCMnn = PCTU3 VERSION
NOTE:nu= THE ACTUAL VERSION
NUMBER AND LETTER
B. iaB11
00 SELECT = 1
Define the Level 1 remote maintenance security code
PASSWORD = 0000
from the System Record Sheet (four digit max.). Level 1
allows remote access to all programs and data.
Default Level 1 security code is “0000.”
OR
c. 01111
00 SELECT = 2
Define the Level 2 remote maintenance security code
PASSWORD = 0000
from the System Record Sheet (four digit max.). Level 2
allows remote entry to Programs 30 m 39 and 77 w 89
only. Default Level 2 security is “0000.”
OR
D. 1 00 SELECT = 8
View the software RAM Checksum. This attribute is not
SUM = xxxxxxxxx
editable. The default checksum may change.
OR
E. 1
00 SELECT = 9
View the PPSU Power Cycle Counter. This attribute is
COUNTER = XXXX
not editable. The counter indicates the number of times
power is removed from the system after
Program 00
was initialized via
Program 90.
6. m
00 SELECT = (0,1,2,8 or 9)
Secure data in system programming.
DATA PROGRAMMED
(Only works for “1” and “2”)
7. m
00 SELECT =
Prepare system for another selection (go back to
step 5), or exit Program 00 (continue with step 8).
1-12