INSTALLATION-PCB
SECTION 200-096-206
FEBRUARY1991
TABLE 6-F
PEMU
CONTROLS,INDICATORS,ANDlNTERFACECONNECTORS
CONTROL/INDICATOR/ 1
CONNECTOR
(Figure 6-9)
TYPEOFCOMPONENT
DESCRIPTION
TIE Line Circuit 1
Indicator CD1 02
Red LED Lights to indicate TIE line 1 is in operation
TIE Line Circuit 2
Indicator CD202
TIE Line Circuit 3
Indicator CD302
TIE Line Circuit 4
Indicator CD402
Lights to indicate TIE line 2 is in operation
Red LED
Red LED
Lights to indicate TIE line 3 is in operation
Lights to indicate TIE line 4 is in operation
E & M TIE Line
Connector J101
E & M TIE Line
Connector J201
Modular connector
Modular connector
Interface connector for E & M TIE line
circuit 1.
Interface connector for E & M TIE line
circuit 2.
E & M TIE Line
Connector J301
Modular connector
Interface connector for E & M TIE line
circuit 3.
E & M TIE Line
Connector J401
Modular connector
Interface connector for E & M TIE line
circuit 4.
FG Jumper P3 Three-terminal jumper 1 Enables or disables -48V ground to FG.
GND/BAT Jumper
PlOl
Three-terminal jumper
M-lead origination for TIE line 1 (must
be in BAT position per FCC requirements)
GND/BAT Jumper
PI02
Three-terminal jumper
M-lead origination for TIE line 1 (must
be in BAT position per FCC requirements)
GND/BAT Jumper
P201
GND/BAT Jumper
P202
Three-terminal jumper
Three-terminal jumper
M-lead origination for TIE line 2 (must
be in BAT position per FCC requirements)
M-lead origination for TIE line 2 (must
be in BAT position per FCC requirements)
GND/BAT Jumper
P301
Three-terminal jumper
M-lead origination for TIE line 3 (must
be in BAT position per FCC requirements)
GND/BAT Jumper
P302
Three-terminal jumper
GND/BAT Jumper
P401
Three-terminal jumper
M-lead origination for TIE line 3 (must
be in BAT position per FCC requirements)
M-lead origination for TIE line 4 (must
be in BAT position per FCC requirements)
6-18