Hardware Restart
To restart the control unit, remove and restore its power by
following these steps:
1
2
3
4
5
6
Turn the power off at the Power Supply Module on the
basic carrier.
If there is an Auxiliary Power Unit, turn the power off.
If there is an expansion carrier, turn the power off.
Turn the power on at the expansion carrier.
Turn the power on at the Auxiliary Power Unit.
Turn the power on at the Power Supply Module on the
basic carrier.
The green power light on the Power Supply Module(s)
should turn on. If the trouble remains after you have
recycled the power, contact the equipment supplier for
assistance.
TESTING OUTSIDE
LINES
In order to operate properly, the system must receive toll-
quality dial tones at the network interface. To perform
this test use a basic rotary telephone, a Touch-Tone
telephone with a modular cord, or a telephone with clip-on
leads.
CAUTION:
Do not use a MERLIN II system voice
terminal for this test. It will not test for dial tones and
may be damaged.
At the network interface associated with the outside line
from which you cannot make a call, choose the
appropriate procedure from among those that follow.
4-56 General Tests