AT&T 518-600-016 Telephone User Manual


 
5
6
7
8
9
10
11
12
Use either Centralized Programming to program the
basic telephone or connect a voice terminal directly to
the control unit station jack where you plan to connect
the OPTI, BTMI, or BTMI-2. To use centralized
Programming, follow the procedures on page 3-81
for
a Display Console or page 3-100 for a BIS-34D
Console.
To change the order in which the system searches for
an available line, follow the “Automatic Line
Selection” procedure on page 3-117. Do
not
include
intercom lines in the sequence.
Set Ringing Options on lines and line pools.
To do
this, follow the “Ringing Options” procedure
on page
3-114.
Remove any custom
features assigned to buttons above
the dial pad.
Disconnect the voice terminal or leave Centralized
Programming.
Leave administration mode by sliding the T/P switch
to the center position.
Connect the basic telephone to the OPTI,
BTMI, or to
the BTMI-2.
Connect the OPTI, BTMI, to the BTMI-2 or the basic
telephone port selected and connect the BTMI or
BTMI-2 to the analog port selected.
Administering Basic Telephones
3-113