AT&T 518-600-016 Telephone User Manual


 
Before connecting a printer to the control unit, make sure
that all modules are installed on the control unit Refer to
Figure 2-23 and the following instructions to connect a
printer to the control unit:
1
2
3
4
Locate the Z200A EMI filter. Notice that the filter is
closer to one end of the cord than the other. Plug the
end of the cord closest to the filter into the SMDR port
of the Processor Module. The SMDR port is the top
port on the Processor Module.
Plug the other end of the EMI filter into the module
jack on the adapter (355AF or 355A). If the printer has
a female connector on its interface cable, use a 355A
adapter instead of a 355AF adapter.
Connect the female connector on the adapter to the
25-pin male connector on the printer’s interface cable.
Set the printer options for use with the Call Report
(SMDR) feature.
> If you have an AT&T 572 printer, set the
programming options on the printer according to
Table 2-10. Refer to the user’s guide supplied with
the printer for further information.
> If you have an AT&T 475/476 printer, set the DIP
switches on the printer according to Table 2-11.
Refer to the user’s guide supplied with the printer
for further information.
2-82 Installing the Control Unit