Chapter 10 Voice Mail
X6004 User’s Guide
112
Figure 93 Configuration > PBX > Server Configuration > Voice Mail
Each field is described in the following table.
Table 27 Configuration > PBX > Server Configuration > Voice Mail
LABEL DESCRIPTION
Voice Mail
Management
Per call Max
Length
Specify the maximum number of seconds for each voice mail message. This value
can be from 1 to 90 seconds.
Per user Max
Usage
Specify the maximum number of seconds for all voice mail messages for each
extension. When a user hits this limit then the X6004 will no longer save voice mail
messages. This value can be from 1 to 300 seconds.
Mail Relay
(Domain/IP)
Specify the domain name or IP address of the mail relay server to which you want
to send voice mail messages.
Mail Relay (Port)
Specify the listening port number of the mail relay server to which you want to
send voice mail messages.
Apply
Click this to save your changes and to apply them to the X6004.
Reset Click this to set every field in this screen to its last-saved value.