Lucent Technologies 518-458-100 Telephone User Manual


 
Specifications
A-2
(continued)
Other Specifications
Specification Description
Switch Fabric
Full digital, nonblocking
Electrical
Specifications
35 watts (120 BTUs/hr) per PARTNER Endeavor 362 processor module during normal power consumption
45 watts (154 BTUs/hr) per PARTNER Endeavor 362 processor module during maximum power consumption
30 watts (105 BTUs/hr) per 362EC expansion module during normal power consumption
40 watts (140 BTUs/hr) per 362EC expansion module during maximum power consumption
45 days to 6 months memory backup with 2 AAA-size standard alkaline batteries (IEC LR03)
Processor Module
Specifications
68306 16 Mhz processor
256Kbyte RAM
512Kbyte FLASH ROM
Custom VLSI DSP ASIC—16bit, 52 Mhz
—VLSI = Very Large Scale Integration
—DSP = Digital Signal Processor
—ASIC = Application Specific Integrated Circuit
Extension Jack
Specifications
(Endeavor
Processor and
362EC module)
Ringing voltage: +55VRMS Balanced ringing within a trapezoidal wave shaping
38- to 42-volt talk battery
Ringing frequency: 20 HZ
Music-On-Hold
Jack Specifications
Accepts 2 volts at 50 Kohms maximum input
0 – 18 dB attenuation
Environmental
Requirements-
Control Unit
Mount on a wall at least 2 feet (0.6 meters) from the floor (wall mounting required)
Locate within 5 feet (1.5 meters) of the network interface jacks and a properly grounded electrical outlet not
controlled by a switch, using supplied 7-foot (2.1-meter) cords
Operating temperature 32° to + 104°F (0° to + 40°C), not in direct sunlight
Humidity 15% – 90%, noncondensing
For proper ventilation and easy replacement of modules, provide the following minimum clearance around the
control unit:
—5-Slot Carrier:
1 foot (0.3 meter) clearance at the top and sides and 2 feet (0.6 meter) at the front and bottom
—2-Slot Carrier or Stand-alone Endeavor processor module:
1 foot (0.3 meter) clearance at the front, top and
right side, and 2 feet (0.6 meter) at the bottom and left side
Locate in an area free of excess moisture, corrosive gases, dust, and chemicals
Electrical
Requirements-
Control Unit
U.S. and Canada: 90-130 VAC, 50-60 Hz, 3-prong outlet separate ground, separately fused at 15 Amps
Grounding to comply with Underwriters Laboratories (UL) 1459:
A. An insulated grounding conductor that is not smaller in size and equivalent in insulation material and
thickness to the grounded and ungrounded branch circuit supply conductors, except that it is green with or
without one or more yellow stripes, is to be installed as part of the circuit that supplies the product or
system
B. The grounding conductor mentioned in item A is to be connected to ground at the service equipment
C. The attachment-plug receptacles in the vicinity of the product or system are all to be of a grounding type,
and the grounding conductors serving these receptacles are to be connected to earth ground at the service
equipment