Lucent Technologies 518-458-100 Telephone User Manual


 
Clearing a Backup-Failure Alarm
6-9
Clearing a Backup-Failure Alarm
If you use Backup Programming—Automatic (#123) and the automatic backup
fails, a Backup-Failure Alarm message appears (instead of the default
day/date/time message) on the top line of the telephone display at idle extensions
10 and 11.
After correcting the problem that caused the failure, you can clear the
Backup-Failure Alarm using the following procedure. (See Figure 2-2 on page
2-19 for the location of special programming buttons such as
s and
e on system phones.)
1. Press
f 0 0 s s # 1 2 3.
The current setting is displayed.
2. Press 3 to choose Option 3, “Backup Alarm Cleared.”
NOTE:
You cannot use D or d in this procedure to choose Option 3.
NOTE:
If an ASA/DXD or PARTNER Voice Mail PC card is in use, perform Backup
Programming—Manual (#124) as described in Chapter 5. Deactivate
automatic backup to prevent this from re-occurring.
3. Exit programming mode.
NOTE:
Using Option 3 to clear a Backup-Failure Alarm does
not
change the setting
for Backup Programming—Automatic (#123). It remains either Active or
Not Active.