Unit Load Calculation Worksheet
Qty x
Unit Load
= Total
Equipment
Hybris/PBX
or Modified
Square
Optional Equipment †
Direct Station Selector ‡
General Purpose Adapter
Hands-Free Unit
Headset Adapter
0.7
0.8
0.8
0.8
0.9
1.0
1.0
1.0
Total Unit Load for Slots 5 and 6
The MFM has its own individual wall power unit located at the telephone and
therefore is not added to the unit load calculation.
Up to two DSSs (one DSS per MXL-28D or MLX-20L) can be powered from each
control unit carrier. For example, a three-carrier system can have six system
operator positions, each with one DSS powered from the control unit.
If the unit load for slots 5 and 6 is less than or equal to 27, auxiliary
power is sufficient for the carrier.
If the unit load for slots 5 and 6 is more than 27, continue to Step 9.
B-8 Unit Load Worksheet