AT&T Release 2.0 Telephone User Manual


 
Installing Telephones and Adjuncts
Supplemental Alerts
Alerting devices notify people working in noisy areas of incoming, transferred,
and inside calls.
Connect a supplemental alert device to one of the following, as described
earlier
in this section:
single-line telephone
MLX telephone with an MFM
supplemental alert adapter (SAA) and analog multiline telephone
NOTE:
See the next section, “Supplemental Alert Adapter (SAA),” for
installation instructions.
The MFM and SAA support devices operating on 48 VDC, Alerts operating on
20-30 Hz can be connected to an MFM or a single-line telephone jack.
Supplemental Alert Adapter (SAA)
When the system forms indicate the installation of a bell, horn, chime, or
strobe with an analog multiline telephone, install the SAA as follows (see
Figure 3-13).
1. Plug the telephone cord into the jack labeled
TELEPHONE
on the SAA.
2. Plug the cord from the
the SAA.
3. Plug the cord from the
UNIT
on the SAA.
alert device into the jack labeled
ALERTER
on
telephone jack into the jack labeled
CONTROL
Installing Adjuncts
3-27