Installing the PC, CAT, or Printer
CAUTION:
To prevent damage from electrostatic discharge (ESD), avoid
touching leads, connectors, pins, and other components. Use a
properly grounded wrist strap.
Connecting a PC (Within 50 Feet)
Use the hardware and procedures in this section to connect a PC to the
control unit when the distance is less than 50 ft (15 m). See Figure 5-1.
Hardware
■ 355AF adapter
■ D8W cord
■ EIA-232-D cable (optional; use only if preferred)
Procedure: Connecting the PC (Within 50 Feet)
1. For system programming or system maintenance, plug one end of a
D8W cord into the SPM jack on the control unit (the lower jack).
NOTE:
For SMDR, plug the D8W cord into the SMDR jack (the upper jack)
instead of the SPM jack.
2. Plug the other end of the D8W cord into a 355AF adapter.
3. If you are using the EIA-232-D cable, connect one end to the 355AF
adapter and the other end to the COM1 port on the PC.
If you are not using the EIA-232-D cable, connect the 355AF adapter
directly to the COM1 port on the PC.
5-2 Connecting a PC to the Control Unit