Installing Telephones and Adjuncts
Table 3-2. - Continued
Color
Yellow
Orange
What It Identifies
Auxiliary circuits
arranged in 3-pair
modularity
Connections from
transmission
electronics equipment,
such as multiplexer or
concentrators
Special Features
For auxiliary circuits
that are not arranged in
3-pair modularity, use
blank labels. If a
system has customized
labels for the auxiliary
system, use them.
Supplied by the
equipment
manufacturers
Labeling 4-Pair Wire and Outlets
It does not matter whether you pull the DIW cable from the telephone to the
control unit or from the control unit to the telephone. In either case, mark one
end of the DIW cable with the location or destination of the other end.
The following procedure is an example of pulling from the telephone to the
control unit.
1. If you do not have labeling instructions on any the system forms, assign
a number to each jack on the floor.
2. Put the boxes of wire near the offices (and jacks) where they have been
assigned.
3. Mark the end of each DIW cable with the number of the jack where the
wire has been assigned.
Connecting the Telephones to the Control Unit
3-69